| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
PDSC form does not match what is installed. Actually have Aquastar 8HP equalizer line covers. - Corrected form submitted and approved. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
More than 25 feet between depth markers. Depth markers shall be no more than 25 feet apart as measured along the perimeter of the pool. Depth markers shall be either a 6x6 inch tile or written in at least 4 inch lettering. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Handrail loose. Maintain secure and in good condition. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed only one functional inlet. Provide functional inlets. - Intent to suspend item.
Provide directional inlet fittings for inlets. Only one, non-functioning inlet with directional fitting. - Intent to suspend item. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Pool built with bench more than 18" wide. Benches should not be more than 18" wide. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope 22 feet long. Corrected to 24 feet long. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate not self-latching. Provide self-closing and self-latching gate. Corrected by operator. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck chairs too close to pool. Maintain at least 6 feet clear walkway around pool. Corrected by operator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flex line used on pool piping. Use rigid Schedule 40 piping. - Intent to suspend item.
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemcals stored in pump room. Store chemicals in chemical storage room. Corrected by operator.
No ventilation in pump room or chemical storage room. Provide either cross or continuous forced air ventilation in pump room and chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Provide air gap for backwash. |