11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed loose hand rail. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed throw rope greater than 30 feet. CDI, rope adjusted to required length while on-site. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Childrent should not use the swimming pool without adult supervision." in 1" lettering. Observed incorrect verbage and size. Lettering at 3/4 in. CDI, corrected on-site.
.2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed lettering at 3/4 inches. CDI, corrected on-site. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Observed vacuum line not capped and providing suction. CDI, cap provided during inspection. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no air gap at backwash line. |