| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent main drain, total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Leaves and branches on pool floor and floating on pool surface. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Water above the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Non-slip treads missing on both ladders. Was an issue last year as well. .2521(b) Ladders shall have slip-resistant tread. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy with new 60 foot throw rope. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both doors to office and back gate not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Back gate corrected. - Pre-permit item.
Windows in the office capable of opening all the way. .2528(a) Ground level windows shall not open greater than 4" on to pool deck. - Pre-permit item.
Foothold on outside of fencing. .2528(b) Horizontals shall not be located less than 45" in height. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone does not ring when calling back to emergency phone. .2530(f) Emergency phone shall remain operable. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
FloVis flow meter not functioning. .2518(g) Keep flow meter operational. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Light not working in pump room. .2533(b) Provide sufficient lighting in pump room.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No floor drains in restrooms. .2526(c) Restroom flooring shall be slip resistant and sloped to drain. Floor drains shall be provided. |