Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePINES AT CAROLINA PLACE, THE
Address12600 WINDY PINES WAY
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 9/30/2024
Final Score @ Grade
40
General CommentsPre-permit inspection conducted with CPO Clay Massenburg and Shohn Beachum. Gate at parking lot swings in towards pool due to topography. If gate is ever replaced, will need to swing away from pool. Blue-White flow meter installed on an elbow fitting, not installed per manufacturer’s instructions. Will need to ensure FloVis flow meter is functioning properly. Pre-permit inspection did not pass 5) 7) 16) 22) 24) There is a $100 re-inspection fee that must be paid by calling our office (980) 314-1620 and paying with a credit card prior to scheduling a re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent main drain, total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Leaves and branches on pool floor and floating on pool surface. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water above the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Non-slip treads missing on both ladders. Was an issue last year as well. .2521(b) Ladders shall have slip-resistant tread.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy with new 60 foot throw rope. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Both doors to office and back gate not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Back gate corrected. - Pre-permit item. Windows in the office capable of opening all the way. .2528(a) Ground level windows shall not open greater than 4" on to pool deck. - Pre-permit item. Foothold on outside of fencing. .2528(b) Horizontals shall not be located less than 45" in height.
22 6 Premises: emergency telephone provided No No No Phone does not ring when calling back to emergency phone. .2530(f) Emergency phone shall remain operable. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No FloVis flow meter not functioning. .2518(g) Keep flow meter operational. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Light not working in pump room. .2533(b) Provide sufficient lighting in pump room. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No floor drains in restrooms. .2526(c) Restroom flooring shall be slip resistant and sloped to drain. Floor drains shall be provided.