| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH <6.8. Acid at >100 ppm. Maintain pH between 7.2 to 7.8. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No acid or alkalinity records. Record weekly. Maintain acid below 100 ppm. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
/Chipping paint on pool steps and around returns. Keep in good repair. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
No weirs in skimmers. Replace weirs. Equalizers plugged in skimmer. Repaired/corrected. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
No Diving faded. Respray in 4" lettering every 25 ft or less. Greater than 25 ft between wall/deck depth markers at shallow. Both sides of steps. Provide wall and deck depth markers 25 ft apart or less. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed slip resistant tread missing on one ladder rung. Replace. Ladder handrails loose. Tighten. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Vacuum line not plugged. Provide cap. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool furniture 4 ft to pool. Maintain 6 ft clearance. Repair damage to deck at 5 ft. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
"Warning: No Lifeguard on Duty" not in 4" lettering. Provide in 4" lettering. "Children should not use the swimming pool without adult supervision" not provided in exact wording. Provide in 1" lettering. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Keep operational. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Water at 113 F in restrooms. Maintain at 110 F or below. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Provide a backflow prevention device on hose bib at deck. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No floor drain in restrooms. |