13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting color band on stairs stops 3" - 6" from pool wall (pool wall at angle @ stairs). ** Re-paint so that bands are at least 1' from pool wall. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Abundant deck cracks. ** Deck needs to be re-surfaced. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
-Forced air ventilation in equipment/ chemical room operates with light switch. ** Fan should run continuously.
- Equipment/ chemical room floor wet due to leaking hose bibs (1 of which is part of water heater). ** Keep room dry. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash pipe extends almost to bottom of sump.
** Provide complete air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Clean restroom fixtures & floors prior to pool opening. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
- Fill spout extends 8" passed pool wall. ** Maximum is 2".
- No backflow prevention on hose bibs - 3 on pool deck, 1 in women's restroom (& one on water heater). ** Install vacuum breakers on all hose bibs. |