Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameNORTHSTONE COUNTRY CLUB-MAIN
Address15801 NORTHSTONE DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/8/2019
Final Score @ Grade
24
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed one equalizer cover missing. PO replaced and secured missing equalizer cover.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor needing cleaning.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Ladders shall have slip-resistant tread. One ladder has a missing tread. .2521 Install ladders per manufacturer instructions. One ladder missing safety end caps.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 3 missing eyelets on returns and vacuum port cover missing. PO replaced all missing fittings and vacuum port cover.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. PO could not locate key to non-used pool gate next to tiki bar, could not verify if self closing/ self latching. Gate securely closed with band clamps.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Hose bib outside guard room needs backflow prevention device.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Backwash pipe has no air gap from height of pit. GENERAL COMMENT: Observed a few depth markers and no diving markers on deck beginning to fade, will need repainting by next pool season. Permit items corrected, permit issued.