12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One eye lid missing from return outlet in pool. Corrected: Eyelid placed into outlet. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Two body hoods had bolts facing inside of hook creating safety risk. Corrected: Bolts turned to outside of hooks. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck, not operating, needs correcting. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Ceiling exhaust fan in chemical room does not appear to be operating. Needs correcting. Be sure door to chemical room is left open at all times for natural cross ventilation of vents in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap from backwash pipes from height of backwash pit. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
MIrrors should be shatterproof. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Observed hose bibs on pool deck, and in men's restroom needing backflow prevention device.GENERAL COMMENT: Permit to be issued |