| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent total alkalinity or cyanuric acid checks. Check daily Cl, pH, main drains and at least weekly CYA and TA. - Intent to suspend item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
PDSC form does not match what is in place. Pool actually has 12 equalizer line covers. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir stuck. Provide functional weirs.
Some skimmer baskets weighted down with rocks. Use only NSF approved skimmer baskets. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder loose. Maintain secure and in good condition. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck chairs too close to pool edge. Maintain at least 8 feet clear walkway around pool. - Intent to suspend item.
Observed one of the anchors sticking up. Maintain deck free of trip hazards. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone unhooked at time of inspection. Provide functional emergency phone. Corrected.
Emergency phone around the corner out of sight. Provide signage alerting bathers to the location of the emergency phone. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not working in pump room or chemical storage room. Provide either cross or forced air ventilation for both rooms.
Leak at pump. Fix leak. |
|