6
General CommentsNIGHT SWIMMING NOT APPROVED PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW REQURIED AT 39 GPM TO 63 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF THE FILTER. GREATER THAN 100 GPM IS A SUCTION HAZARD FOR DRAIN COVER.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash line.