Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed one (1) vacuum line with no plug in place. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing or damaged skimmer basket. Observed one cracked basket. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
.2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies.
Observed one set of depth markings and no dive markings between 5 ft and 4.5 ft depth markings at pool side and pool interior nearest entrance at a distance of 26 feet and 5 inches. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Observed one (1) pool ladder with no safety caps at pinch points. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
.2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area.
Observed no second ring buoy and throw rope at pool with surface area greater than 3,000 sq. ft. Surface area. |