2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm.
Unable to read chlorine level. As soon as reagents added solution turns clear. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
During inspection observed 6HP covers on lines and approved PDSC form states there should be 4HP. CDI facility removed 6HP covers and replaced with4HP. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Observed height of fence that was less than 48". Pre-2010 no permit action taken but must be repaired. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair.
Observed cracks in decks that were less than 1/2" but in need of repair. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
.2524(c) Lighting fixtures shall not present a hazard to the public.
Observed light cover in pool that was removed. CDI light cover replaced to cover previous hole. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
Observed bags of chemicals that were stored on floor. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2626(m) Keep restrooms and fixtures clean and in good repair.
Observed toilet in mens restroom covered in brown fecal matter. In need of cleaning. |