8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets. CDI: cleaning during inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed 2 missing escutcheon plates on 3ft side handrail and 4ft side ladder. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for both sets of ring buoys to be > 50ft in length. CDI-rope length was cut to appropriate length of 50’. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). Observed lawn chairs and chairs < 8ft from pool edge. CDI: chairs moved back to provide 8ft clearance.
.2537(2) Decks shall be kept in good repair. Observed some minor gaps in deck concrete. Not enough to create a trip hazard. CPO informed me that pool is set to have a deck repair/redo the next pool season 2025. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed emergency phone sign not posted and sitting on a table not visible to pool users. CDI: sign was posted on wall by phone where it was visible during inspection. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed bags of aqua salt stored on floor of storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(k) Provide shatterproof mirrors. Mirrors in restrooms not shatterproof. |