Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed facility with a new pentair intellifllow pump installed. Pump does not match what is listed on the PDSC form. Submit new PDSC form for approval. Permit denied.
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed pool having two vacuum lines according to CPO. One vacuum line is missing a cover, the other vacuum line has a self closing self latching cap which does not latch properly. Permit denied |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding 50ft. CPO cut rope to 50ft. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching. Observed the door leading to restrooms and gym not self-latching. Permit denied |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed deck chair within 6ft of waters edge. CPO relocated chair. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed facility without a sign with this statement in exact lettering and size requirements. Permit denied
.2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed facility without a sign with this statement in exact lettering and size requirement. Permit denied |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed dialing instructions on sign stating “dial 911” facility has a 3 kings box which consumer has to push a button to call 911. CPO corrected sign during inspection. |