Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGLENHAVEN APARTMENTS
Address3117 TACOMA ST
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/25/2018
Final Score @ Grade
24
General CommentsMost issues from previous inspection corrected. Records are not yet being kept. Ensure that Cl, pH, main drains, and pool maintenance activities are checked and recorded daily. Record at least weekly total alkalinity and cyanuric acid. Anchor for handrail broken. Maintain handrail secure and properly installed. Pump motor not bonded to the pool. Did not observe a bonding wire. Ensure that outlet for newly installed liquid chlorine and acid system is properly installed. Ensure all required Code Enforcement permits are obtained. Permit #18-600049 issued. Permit issued with the following conditions: No Night Swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level above the skimmers. Maintain proper water level so that skimmers function properly. Corrected by operator.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Floor return cracked. Replaced by operator.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No New body hook and 12 foot pole missing screws. Removed by operator. Will use old pole until can get screws for it.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not-self closing. All gates shall be self-closing and self-latching. Corrected by operator.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Table too close to pool. Maintain at least 5 feet clear walkway around the pool. Corrected by operator.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan for chemical storage part of pump room tied to light switch. Fan for pump room part of pump room not functioning. Provide either cross or forced air ventilation. Fan shall run continuously and not be tied to the light switch.