3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH < 6.8. Maintain between 7.2 and 7.8. - Immediate item |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed two records from the end of May, no other records observed. Check daily Cl, pH, main drains and at least weekly cyanuric acid and total alkalinity. Pools usually closed on Mondays, this should be reflected in the pool log. - Intent item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
One equalizer line cover missing. Install A112 approved equalizer line cover. - Immediate item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer missing weir. Install functional weir. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting color band currently tiled diagonally with wide gaps between tiles. Provide at least a two inch wide contrasting color band within one inch of step edge if using tile, or at the edge if painted. - Intent item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope tied to fence. Rope cannot be tied to fence. Corrected by operator.Throw rope too long. Corrected to 30 feet by operator. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Observed chlorine tablets in all three skimmer baskets. Use only NSF approved chlorinator for chlorinating the pool. Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace.Provide spare pump basket. None observed. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan in pump room tied to the light switch. Fan shall run continuously. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Not all pipes labeled. Label pipes. |