5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Pool record does not include a column for main drain checks. ** Check main drains daily & indicate on pool record form. Gave MCHD sample monthly pool record form. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
One equalizer line cover missing. ** Install (same make/ model as others). Immediate suspension |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Missing 1 of 3 weirs. ** Install. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope around ring buoy dry rotted & throw rope dry rotted. ** Replace buoy. New rope on-site. Ring buoy must be US Coast Guard Approved. Immediate suspension. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Lack sign "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION'. Letters must be at least 1" in height. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water @ lavatory in restroom 125.4F. ** Maximum allowed is 110F.
Restroom lavatory, toilet & floor need to be cleaned. ** Clean all. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Observed hose down in pool water & is the means that water is added to the pool - hose bib does not have any backflow prevention. ** Install vacuum breaker on hose bib. |