Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOFFEY CREEK APARTMENTS II
Address2108 DIAMOND CREEK CIRCLE
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/13/2015
Final Score @ Grade
18
General Comments#13 Contrasting color tiles on stairs at least 1 1/2" from leading edge of steps. ** Tiles should not be any greater than 1" from leading edge. #30 No backflow prevention on hose bibs in restrooms. ** Install vacuum breakers. Over-the-rim spout extends ~4" beyond pool edge. ** Maximum is 2". PDSC form has been submitted & approved. POOL PERMIT CAN BE ISSUED.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer basket full of debris. ** Corrected during inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Coping damage/ chipped in at least 2 areas. Deck has places where concrete is chipped out & 1 patched area at ladder is now raised. ** Repair.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum port attachment in place on pool wall. ** Attachment removed & protective cap installed.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Equipment room does not have any natural cross draft ventilation or forced air ventilation.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash pipe inserted into larger pipe in floor. ** Backwash water should discharge through a complete air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in restrroms. ** Provide.