Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCEDARFIELD PARK
Address9000 TORRENCE CROSSING DRIVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/18/2026
Final Score @ Grade
12
General CommentsNo Night swimming Inspection completed with CPO Danielle Parker Pump has been changed. Verified the following during inspection: 1. Permit Restriction: Flow meter must remain operable. Flow required at 105 gpm to meet turnover and flow restriction of the filter. Flow greater than 150 gpm exceeds main drains. Suction Hazard. 2. New Pump: Hayward HCP 3000 Series HCP3020VSP, 2.7 THP 3. Aquastar flow meter reading the above flow range. Flow was 105gpm 4. Main Drain, skimmer and return line all 2.5” pipe 5. (2) Aquastar 914xxx 2017 drain covers. 6. (1) Pentair TR140 filter 7. (4) skimmers with (4) Aquastar 6HPHAxxx EQ line covers. 8. 6 returns, on pool wall

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2514(c) Pool finish shall be white or light colored. Observed some staining of the pool floor. Repair by resurfacing pool floor.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed deck chairs within 6’ of pool edge. CDI; chairs moved back. .2537(2) Decks shall be kept in good repair. Observed some gaps in areas pool decking that needs to be resurfaced and filled in. No trip hazards observed.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(m) Keep restrooms and fixtures clean and in good repair. Observed restroom flooring with peeling paint. Floors need to be resurfaced. Observed light out in men’s restroom.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow on deck hosebib.