Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHALF MOON BAY
Address17804 HALF MOON LANE
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/17/2026
Final Score @ Grade
22
General CommentsNo Night swimming. Permit Restriction: Flow meter must remain operable. Flow shall not exceed 119 gpm due to drain Cover Flow restriction. Suction Hazard

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Floating pollen debris in pool. Operator cleaning during inspection. .2537(14) Keep pool surface and pool floor free of debris.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Side access gate did not self close due to decorative rocks preventing closing. Rocks were moved.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Pool furniture located within 6’ of pool edge. Moved during inspection.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Posted telephone number was incorrect. Correct number was written by operator, and verified with 911 dispatch.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter observed stuck during inspection. Repaired by operator.