Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHALF MOON BAY
Address17804 HALF MOON LANE
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/14/2022
Final Score @ Grade
12
General CommentsNight swimming not permitted. Note: Acid feeder system in place in the pump room disconnected not in use. Pressure switch is present, however, since system is not set up or in use, EHS unable to verify that chemical feeder system would stop in the event that the pump system stopped. Operator noted that they do not intend to use the system this season.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris accumulation in skimmers.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Horizontals shall not be located less than 45" in height. Fence constructed pre 2010. Electrical box and phone box installed such that distance between footholds and next horizontal less than 30”. Electrical box 20”, phone box 18”.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed offsets in travertine decking from chipping and seasonal weathering leading to potential trip hazards. CDI - operator filled during inspection.