3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH corrected to 7.8 during inspection |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Missing bumper, ladders should be > 6" from the pool wall |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Replace light bulb, natural cross or continuous forced ventilation required |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
2" air gap required |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Fill spot > 2" from pool edge |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
Hose bib for pool at pump room, which is > 100' from pool |