11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladder rungs to be 8.5" from pool wall on both ladders. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed fence to be 45" in a few spots to the left of restrooms. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed no extra pump basket onsite. .2518(e) Provide a spare basket for pump. CDI: Operator provided pump basket from vehicle. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed hose bibs without backflow prevention device. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. |