| Name | YMCA HARRIS KIDDIE POOL | | Address | 5900 QUAIL HOLLOW RD
| | | | City/State/ZIP | | | Premise Type | 50 - Seasonal Swimming Pool | | County | Mecklenburg | | Inspection Date
| 7/10/2024 | | Final Score @ Grade | | | Inspection completed with David Williamson present.
See notes below for plan review information.
A. Permit Restriction - Flow meter must remain operable. Flow shall be kept at 43 gpm to 104 gpm or less to meet turnover and flow restriction of return pipe. FLOW AT 85GPM
B. Pentair Intelliflo3 VSF 011077, 3 hp pump. VERIFIED AND ACCURATE.
C. FlowVis flow meter reading above permit restriction. FLOW AT 85GPM.
D. Main drain, skimmer and return line all 2” pipe. VERIFIED AND ACCURATE.
E. (2) Aquastar 2008 24xxx drain covers. VERIFIED AND ACCURATE.
F. (2) Pentair TR100 filters. COULD NOT VERIFY FILTER INFORMATION (DATA PLATE INFO WORN OFF).
G. 6 returns. OBSERVED 6 RETURNS
H. (4) skimmers with EQ lines plugged per State recommendations. OBSERVED 4 SKIMMERS WITH PLUGGED EQ LINES. |
|