11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Greater than 75' between ladder & handrail at stairs.
** Spacing should be 75' or less. Pool needs another ladder properly placed. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
2 coping bricks loose & mortar missing between 2 coping bricks. Some deck bricks chipped with at least 1/2" offsets. ** Corrected while on-site.
Note: Cracks in concrete decking & some chipping. Pool deck/ coping needs to be re-done. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Forced air vent in equipment/ chemical room inoperable (& no natural cross ventilation). ** Repair/ replace fan. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to larger pipe in floor (sump). |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No back flow protection on hose bib on pool deck.
** Install vacuum breaker. |