3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH measuring at 8.2. CDI: CPO lowered pH to 7.8. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets full of debris. CDI: CPO cleaned and emptied skimmer baskets. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed body hook with no screws to securely attach to 12 ft pole. CDI: CPO secured body hook with two screws. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
.2524(d) Provide sufficient underwater lighting. Observed 3 out of 5 underwater lights not operating properly. EHS will be following up with CPOs to ensure lights are functioning properly. CPO stated that they will send video of all lights functioning properly.
.2524(a) Pools that are to be used at night shall have sufficient artificial lighting provided. Observed two lights not functioning on pool deck. Pool has 11 other functioning lights. Lighting is sufficient for night swimming, however EHS will be following up with CPOs to ensure lights are replaced. CPO stated that they will send video of all lights functioning properly. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Observed flow meter stuck. CDI: CPO adjusted flow meter and it is now operational. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping and valves not labels with direction of flow. CDI: CPO labeled piping and valves. |