| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Provide toilet paper on a toilet paper roll in men's restroom. |
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
No chlorine. Maintain at 1ppm or greater. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records. Check daily Cl, pH, main drains and at least weekly total alkalinity and cyanuric acid. Left new sheet with CPO. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Vacuum port in place and uncapped. Vacuum line on in pump room. Port shall be removed and plugged when not in use. NOTE: Vacuum port cemented in place. Will give 30 days to make vacuum port meet standards.
Note: Vacuum line closed by operator. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One basket full. Clean regularly.
Equalizer line cover by steps loose. Install snugly and close to pool wall. |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
Safety rope not in place. Provide 3/4" diameter safety rope with floats spaced no more than 5' apart. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Some inlet fittings missing. Provide functional directional inlets. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Provide signage in at least one inch lettering stating "Children should not use the swimming pool without adult supervision". |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone unplugged. Corrected.
Number posted does not match what 911 has. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak in pump room. Fix leak.
No ventilation in chemical storage room. Provide either cross-draft or forced air ventilation. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Post sign stating shower before entering the pool. |