Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTWO20 @ BRANCHVIEW APTS
Address220 BRANCHVIEW DRIVE
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/22/2026
Final Score @ Grade
16
General CommentsPDSC form verified to be in compliance during today’s inspection. All critical items corrected during today’s inspection with CPO Jose Baez. Office door access is occupied and self closing with an audible alarm. Gym doors remain locked at all times. EHS will return by no later than 5/22/26 to verify repairs to water backing up in pump room. See #25 (.2533(d)). Not permitted for night swimming. Permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Concrete deck has minor cracks under side steps at 3 1/2 ft and at edge of pool near 8 ft. CDI - CPO repaired.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Address and pool telephone number not posted at emergency phone. CDI - CPO posted location and emergency contact # at phone.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed grey water backing up and pooling on floor in pump room during back washing. Repair.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Observed missing arrows or labels for the pump room piping.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed a directly plumbed drain pipe for backwashing.