Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTWO20 @ BRANCHVIEW APTS
Address220 BRANCHVIEW DRIVE
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/1/2025
Final Score @ Grade
16
General CommentsInspection completed with CPO, Jose Baez Interlock tested and operational. CPO log records begin today. Office door access is occupied and self closing with an audible alarm. Gym doors remain locked at all times. Permit issued

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(10) Diving equipment and pool slides including stairs and railings shall be kept in good working order. Observed loose hand rail on the far side of the pool. Tighten as soon as possible.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Concrete deck has minor cracks near far side steps and ladder closest to gym.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Observed unlocked pump and chemical rooms. Keep locked while not in use.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Observed missing arrows or labels for the pump room piping.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed a directly plumbed drain pipe for backwashing.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Observed 141 degree water for the restroom hand sinks.