3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH at 6.8. pH must be 7.2-7.8. Facility placed on E status due to pH less than 7.2. Pool closed sign must be posted. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed missing days from daily records. Facility must maintain records daily. Facility must also check drain covers on daily records. Possible Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed equalizer line plugged in 1 skimmer. Equalizer line must remain unplugged. CDI plug removed from equalizer line. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed vacuum port not covered with protective cap. Vacuum port must remain covered with protect cap when not in use. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed 2 ring buoys. One buoy did not have a rope the other buoy did not have rope attached and rope provided was greater than 30ft. CID one ring buoy was removed. 30ft rope was attached to second ring buoy. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gate missing locking mechanism making gate not self-latching. Gate must be self-closing, self-latching. Possible Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed damage on several areas of deck. Deck must be free of trip hazards. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed no ventilation in pump/chemical room. Facility must provide forced cross ventilation. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Observed pump pipes and flow not clearly labeled. Pipes must be clearly identified. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no air gap on backwash line. Provide at least a 2in air gap. |