Inspection Date 6/10/2015
Final Score @ Grade
38
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH at 6.8. pH must be 7.2-7.8. Facility placed on E status due to pH less than 7.2. Pool closed sign must be posted.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed missing days from daily records. Facility must maintain records daily. Facility must also check drain covers on daily records. Possible Intent to Suspend issued.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed equalizer line plugged in 1 skimmer. Equalizer line must remain unplugged. CDI plug removed from equalizer line.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed vacuum port not covered with protective cap. Vacuum port must remain covered with protect cap when not in use.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed 2 ring buoys. One buoy did not have a rope the other buoy did not have rope attached and rope provided was greater than 30ft. CID one ring buoy was removed. 30ft rope was attached to second ring buoy.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gate missing locking mechanism making gate not self-latching. Gate must be self-closing, self-latching. Possible Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed damage on several areas of deck. Deck must be free of trip hazards.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed no ventilation in pump/chemical room. Facility must provide forced cross ventilation.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Observed pump pipes and flow not clearly labeled. Pipes must be clearly identified.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap on backwash line. Provide at least a 2in air gap.