Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWINDERMERE APARTMENTS
Address301 QUEENS ROAD
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/20/2018
Final Score @ Grade
18
General CommentsPDSC verified by JPerry. Could not locate model on pump, but it does match the picture in the pool book. HP on motor is greater than HP on pump PDSC form. Motor is 1.65HP. Could not verify audible alarm or 4" max opening on the residential windows that open to the pool. Foot hold present by fence. Pre2010 pool is not required to correct this at this time.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
13 4 Pool maintenance: contrasting band on steps and benches No No No .2521 Use of contrasting color tiles installed in the stair tread is acceptable provided the tiles are spaced no more than one inch (2.5 cm) from the edge of the tread or from adjacent tiles. Tiles are currently 2 inches from the edge of the tread. Must be repaired before next year's permit.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Due to egress on one gate, it must swing into the pool. Front gate was not self closing. It stopped at the latch. Latch was oiled and door self-closed during inspection.
22 6 Premises: emergency telephone provided No No No .2530(a) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Emergency phone wasn't visible because it wasn't labeled as such and it looks like an electrical box. Pool supervisor labeled box during inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Piping was better labeled.