15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy throw rope in poor repair (two pieces of rope tied together to make one piece). CDI- entire rope replaced with new rope. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 6 inches underneath fencing in some areas. Pool built prior to 2010 therefore no permit action taken.
The distance between horizontal fence members should not be less than 30 inches for pools constructed prior to 2010. Observed distance between fencing horizontals at 29 inches. No permit action taken due to age of pool. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed faded signage. CDI- repaired. |