Inspection Date 5/23/2019
Final Score @ Grade
16
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Maintain ladder in good repair. Observed ladder with right handrail loose. CDI - Operator tightened ladder during inspection. -2-
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length in pool information 42 ft. Today, rope was 48 ft. CDI - Operator shortened rope during inspection. -6-
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed no sign posted at beginning of inspection. CDI - Operator found sign in pump room and posted during inspection. -4-
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed end of pipe for filter backwash below flood plane in sump. -2-
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2626(i) Water in restrooms shall not exceed 110 F. Observed hot water in handsinks at 112-114F in both restrooms. CDI - Operator adjusted temperature on hot water heater and water below 110F. -2-