| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Observed some soil on ladders (inset) steps & some on pool wall & floor. **clean. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Missing 1 escutcheon @ top & the other not secure at bottom 1 rail @ steps. **correct. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed 2 deck cracks & pieces of concrete missing/broken @ edge of "new" concrete area. **repair deck @ edge of new concrete. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak @ top of one filter & therefore, floor wet. **repair filter.
Forced air vent in equipment room inoperable. **repair.
Forced air vent in chemical room operates on switch. **leave fan on @ all times. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash line down in sump. **should have air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Replace broken shower handles (2 in womens).
Handicap "hose" nozzles missing in both restrooms.
Handicap bench in men's shower broken. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Install vacuum breakers on all hose bibs (1 by storage room, 1 in equip., 1 in chem.) |
|