2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.6. CDI - CPO corrected to 1.0 during the inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".
Observed >4" between fence verticals (Pool built in 1993)
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed footholds- lights on the exterior of the pool fence less than 48” (measured at 23”) - Pool built in 1993 |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed no sign for emergency phone location. CDI - CPO stated the location on the Pool Rules sing - Phone is located across from the restroom, pool is located within 75ft from the entrance of the pool |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash. Provide a 2” air gap. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow preventer on hose bib. Provide. |