Premises Information

Return to Inspections
NameWOODLAND ESTATES
Address6147 WINGED ELM COURT
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/29/2026
Final Score @ Grade
32
General CommentsNote: Glass used in fireplace. Could not verify as tempered glass. Recommend removing unless glass is tempered. Intent to Suspend issued for: .2535 - provide DPD-2 reagent; maintain daily record keeping for chlorine, pH and main drain checks; weekly record keeping for total alkalinity and cyanuric acid. A CPO shall be present at the property daily for management of the pool. .2518 - install weirs per mfg. instructions. .2528 - install window limiters at 4" or less on windows that open on to pool deck; doors from restrooms shall self-close, self-latch or self-close with audible alarm. .2537 - clean areas where water is pooling on deck - deck shall be slip-resistant. .2535 - Chlorine and acid tied into same return line to feed into the main return line back to the pool. Presents hazard. Chemicals should not be mixed to prevent hazard. Chlorinate/acid feed through an approved system. .2518 - Provide spare pump basket for the pump - Pump shall be set where combined flow of flow meters at 122 gpm to 148 gpm. Wanda Sanchez present during the inspection. Note: No paper towels in men's restroom. Provide paper towels. Note - Pump room plumbing run with (1) main drain line, (4) separate skimmer lines and (2) separate return lines. Permit Restrictions: 1) Both flow meters must remain operational. Combined flow range shall be from 122 gpm to 148 gpm to meet turnover and flow restriction of the filters. Combined flow shall not exceed 170 gpm due to drain cover flow restriction. Suction Hazard. 2) (1) of 2 doors of double doors must remain permanently affixed or both doors shall be equipped to self-close with audible alarm.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No DPD-2 reagent expired. Replace expired reagent. Provide a log book for record keeping. Maintain chlorine, pH and main drain checks daily. Maintain total alkalinity and cyanuric acid readings weekly. Provide CPO certification for current CPO. Permit denied for all items.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algae on pool walls. Continue to monitor and treat as needed. Automated feeder not operable and facility is manually feeding which may be adding to algae issue.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer weir upside down and (2) skimmer weirs missing. Replace weirs where needed. Install skimmer weir per mfg. instructions, right-side up. Permit denial.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Windows from clubhouse that open on to pool deck (two windows on left side) without limiters. Windows shall be limited at 4" or less. Permit denial. Doors from restrooms do not self-latch. Doors shall self-close, self-latch or self-close with audible alarm. Permit denial.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Multiple areas on pool deck with pooling water. Areas appear to be slick. Eliminate pooling water and clean areas so decking is slip-resistant. Permit denial. Expansion joints with deck cracking/damage. Repair prior to 2027 operating season.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automated feeder unplugged. No stick feeder provided. Chlorine and acid tied into same return line to feed into the main return line back to the pool. Presents hazard. Chemicals should not be mixed to prevent hazard. Chlorinate/acid feed through an approved system. Permit denial.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pump required set to a flow where combined flow range is from 122 gpm to 148 gpm. Pump currently set and combined flows at 115 gpm. Pump shall be set to meet permit restriction. Permit denial. No spare pump basket for the pump. Provide spare pump basket for pump. Permit denial.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Shower not operable on pool deck. Shower shall be operable.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Provide backflow prevention device on hose bib in pump room. No backflow prevention device.