Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator.
Chlorine observed at 0ppm at time of visit. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8.
PH observed at 8.0 at time of visit. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide weekly recordings for cyanuric acid and total alkalinity.
Record log missing section for Cyanuric acid. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions.
Drain covers on walls missing ring required by Aquastar in A10 installation instructions. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris.
Algae observed on pool walls and floor. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs.
All weirs missing. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
One faceplate missing. Another outlet pipe protrudes too far and missing a fitting. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep the flow meter operational.
Flow meter not operational at time of visit.
.2518(h) Any variable speed pump or single speed pump utilzing a VFD shall be capable of maintaining turnover.
Pump turned off at time of visit. Pump must be running at 3450 RPM to meet flow requirements of the system. |