Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVILLAGES APARTMENTS
Address1600 VILLAGE BROOK DR
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 3/29/2017
Final Score @ Grade
22
General CommentsPool CPO Donald Jones obtained new license with effective date of 3/9/17 (Basic LAFT Registration No. 030917-80). EHS obtained copy of the certificate for MCHD records. POOL PERMIT CAN BE ISSUED. Post pool permit in visible location.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No VGB information on PDSC form verified in field and based upon information provided, the pump information is incorrect. Pentair Challenger pump is not model # CHII-NI-2F (w/ max pump flow of 139gpm), but a Pentair Challenger pump model # CHII-NI-2A (w/ max pump flow of 95gpm). ** New PDSC form (w/ corrected information) completed by CPO while EHS on-site. K. Wilson (MCHD Sr Env Health Spec.) to give final approval of form.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope that is part of ring buoy/(circles buoy ) is dry rotted. Throw rope on ring is ~48' long. ** New ring buoy obtained and a new throw rope (@ required 50' length) obtained and attached to the new ring buoy while EHS on-site.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Wide gap with clearance up to at least 7" (due to soil erosion) in one area under straight section of fence line. ** Maximum clearance allowed between grade & bottom of fence is 4". Problem corrected during inspection by installation of heavy rocks.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No natural cross draft ventilation or forced air ventilation in equipment room or chemical room. Both rooms have high & low vents installed in the doors though; however, chemical room door vents have been covered with card board to prevent freezing of plumbing pipes. ** See .2533 (e) and .2534(3). 2 containers of lighter fluid removed from chemical storage room shelves while EHS on-site; one container was located beside open bag of pool shock. ** Maintain safe storage of all chemicals.
27 2 Equipment room: filter backwash discharged through an air gap No No No Back wash pipe inserted down into larger pipe in equipment room floor. ** Back wash water should discharge through a complete air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water at least 129.9F at lavatories in restrooms. ** Maximum temperature allowed is 110F. CPO turned down thermostat on hot water heater while EHS on-site.