Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVILLAGES APARTMENTS
Address1600 VILLAGE BROOK DR
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 3/24/2015
Final Score @ Grade
12
General Comments#8 One skimmer basket broken/ deteriorated. ** Replaced while on-site. #17 Holes in deck where volley ball net posts used to be inserted and at obsolete over-the-rim spout connection site (no piping inside equipment room for over-the-rim spout). ** Plug holes or fill. #25 -- Equipment room & chemical rooms do not have forced air or cross ventilation. Ventilation means are 2 vents in each door. -- Equipment room floor wet due to leak at pump for fountain circulation. ** Repair to keep room floor dry. Pool permit can be issued once PDSC has been submitted & approved by the Mecklenburg Count Health Department.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No -- Gaps up to 9" under some areas of straight fence line. ** Fill dirt added while on-site. Compliance met. -- 2 wrought iron gates. CPO reports that gate accessed via curve in road is kept locked due to safety concerns (blind spot). Gate that is used opens towards pool. ** Gate should open away from pool. Correction of gate swing direction would require wrought iron work. EHS' supervisor will make decision as to whether gate swing direction must be changed.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter float stuck. ** Corrected while on-site.
27 2 Equipment room: filter backwash discharged through an air gap No No No Filter backwash pipe is inserted into larger pipe in equipment room floor. ** Complete air gap should be present.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No back flow prevention on hose bib in chemical room (& pool water is added via hose). ** Install vacuum breaker.