Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDILWORTH EDGE CONDO ASSOCIATION
Address2642 PARK RD
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/7/2021
Final Score @ Grade
18
General Comments*PDSC information verified on site*

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Rungs on both ladders more than 6” from wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope longer than required length. Cut down to 36 ft.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Gate not able to self latch. Gate repaired during inspection. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). More than 4” (pre-2010 construction) under gate and fence (in back). Gate repaired during inspection. No permit action on fencing due to pre-2010 construction. .2528(b) Decorative cut-outs on fence and/or gate shall not exceed 1.75 inches. Cut outs on gate larger than 1.17 inches. Material placed over cut outs.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Repairs need throughout decking.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. No lighting provided in pump room.