Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTROPICANA
Address3010 CROSBY ROAD
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 8/22/2022
Final Score @ Grade
22
General CommentsREHS recommends making a more noticeable sign to help identify location of pool phone. Pool is not permitted for night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in surface skimmers. Removed during the inspection by CPO.
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Observed buoys bunched up and not 5 ft apart. Corrected on site by CPO.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Observed ladder at a greater distance that 6 inches from the wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Brand new rope was cut top 33 feet.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed a few trip hazards on the deck.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. No lighting or ventilation present inside of pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No suitable air gap for backwashing.