Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTHURINGER COURT
Address2771 VON THURINGER COURT
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/29/2021
Final Score @ Grade
20
General CommentsGeneral comment - observed minor plaster cracking/flaking on pool floor in deep end. Due to expected deterioration over season, pool plaster may need to be evaluated for significant repair prior to permitting 2022 season. Pool not approved for night swimming. Intent to suspend issued for replacement of missing skimmer weir.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Debris present on pool floor.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Surface skimmers shall be installed per manufacturer's instructions. Missing weir on skimmer basket near stairs. Intent to suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Flat head bolt/screw protruding from side of ladder. PIC repaired.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Distance from ground to bottom horizontal bar is as much as 8 inches in some areas and consistently greater than 4 inches around entire pool premiere. Pool built prior to 2010 Distance between horizontals on fence measured up to 5 1/2 inches. Pool built pre 2010.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Pool chairs within 3 feet of pool edge. Chairs pushed away from pool.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap.