7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Observed cleaning needed on pool floor. Main drains still visible.
.2537(14) Keep pool surface and pool floor free of debris. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Repeat Observed gaps measuring 6 inches in several areas under fence. Observed fence to measure 45.5 inches in several areas. Observed lattice fence squares to measure 2.75 inches. Observed spaces between fence rung to be 5.5 inches.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Mesh shall not exceed 2.25" square. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Repeat Observed two phone numbers listed on emergency phone instructions. CDI: Incorrect phone number taped over.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Repeat Observed hose bib without backflow prevention on pool deck. Hose is corroded onto hose bib and would not come off. CDI: Backflow prevention device placed on the end of hose. Observed pump room floor to be wet.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
.2533(d) Pump room floor shall be kept dry and free of standing water. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Repeat Observed backwash pipes to be connected without an air-gap. Cut end of pipe to create air gap.
.2513(b) Filter backwash shall be discharged through an air gap. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Repeat Observed shower to not have handles or be operable.
.2626(h) Shower(s) shall be provided. |