16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed clearance up to 7 3/4" below lattice fence line and lattice fence squares are 2 3/4" x 2 3/4". Observed clearance under wrought iron fencing at 6 1/4" and space between vertical mem['p;/mbers of wrought iron fencing up to 5 1/2". |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
An incorrect phone number listed on emergency pool phone. CDI, pool operator crossed out old phone number with marker and only the proper number is showing. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(b) Provide sufficient lighting in pump room. Observed light not working in pump room.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed mechanical ventilation not working.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed no back flow provided at hose bib near pump room.
.2533(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed pool chemical bag stored on ground. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
.2626(h) Shower(s) shall be provided. Shower not operable during visit. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |