| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine so high it bleached out reagents. Maintain safe chlorine levels. Thiosulfate added by operator and reduced to 3ppm. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Single main drain pool. PDSC form has Stingl switch. Pool has Vac-Alert for SVRS. Provide updated PDSC form. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor dirty. Clean regularly. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Some of the depth markers on the pool deck with incorrect depth. Corrected by operator. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope too long. Corrected by operator to 36 feet.
GC: pole for body hook bent. Recommend replacing with new pole. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fence with footholds. Ensure that fence is 48" high with no footholds. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Posted pool hours 8:30 AM to 9:00 PM. Pool has insufficient lighting to allow for night swimming. Change pool hours to 8:30 AM to dusk or similar hours. Corrected by operator.
GC: underwater light not tightly secured to the wall. Recommend tightening screws or reseating underwater light. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Pool using automatic feeders. Chlorine > 20ppm. Ensure that feeders are properly calibrated. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Provide spare pump basket for pump. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet. Keep floor dry, keep dry.
Inadequate ventilation in pump room. Provide either cross or forced air ventilation in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
One of the pipes not labeled. Corrected by operator. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash is directly onto the lawn behind the pump room. Recommend installing a backwash pit and connecting to sewer. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower drain clogged. Unclog shower drain.
Drain cover for shower drain missing. Provide shower drain. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Provide toilet paper holder for toilet paper in restrooms. |