11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder rungs 7" from pool wall. Maintain 3" to 6" between ladder rung and wall. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Electrical conduit line outside of barrier provides foothold. Eliminate foothold.
Observed 44" between horizontals on fencing. <48" on some areas of fencing. Pool built pre-2010.
General Comment - Front gate on right side from entry <48" due to slope in cement. Not noticed on previous inspection. Facility will repair prior to opening to the public. Operator will provide photograph documentation. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Fill line does not meet .2512 requirements. Original construction. If ever replaced, bring to code. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No floor drains in pool restrooms. Pool original construction. Provide floor drains. |