15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy grab rope degrading. Replaced during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fence less than 48" in height near main entry area. Pool built 1976. Maintain fence height of at least 48".
Note - Gate approved. Pool built 1976. Distance between horizontals less than 45". Meets grandfather of rule. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap.
Fill line does not meet rule .2512 with ASSE listing. If replaced, replace with approved check valve. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib or floor drains in pool restrooms or pump room. Provide hose bibs/floor drains. |