Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTONEHAVEN HOMEOWNERS ASSN
Address6615 THERMAL RD
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/21/2022
Final Score @ Grade
22
General CommentsPermit restrictions- throttle valve must remain locked in place with pressure gauge installed flow meter not to exceed 226 gpa per the measurements. Pool not permitted for night swimming. PDSC verified.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No **.2537(14) Keep pool surface and pool floor free of debris. Observed debris along the pool floor.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris inside of the skimmers.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Observed both ladders at 7 inches away from the pool wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope was too short at 40 feet . CDI Ring buoy rope replaced during inspection to meet 42 feet in length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 4 inches under fence in distance. .2537(b) All gates and doors shall be self-closing, self-latching. Gate was not self-closing, self-latching initially. CDI- Gate was repaired on site to become self-latching, self closing by CPO.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash