Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed plexiglass at bottom of fence broken. Replace at any gate where missing or broken.
.2537(b) All gates and doors shall be self-closing, self-latching. Observed door to bathrooms not self closing or self latching. CDI-alarm installed. Gate where AC unit and half wall not self closing self latching. CDI-gate permanently shut. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair. Observed deck with >1/2 inch offset. CDI-crack repaired with cement |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed leaks at filter and backwash spyglass. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(k) Provide shatterproof mirrors. Observed mirrors not shatterproof |