Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Main gate is a double gate. Observed pole able to be pulled up to gain entry to the pool.
Pole secured during inspection.
Observed pool fence made of bricks allowing for handhold/foot hold up the side. Pre 2010 fence.
.2528(b) Decorative cut-outs on fence and/or gate shall not exceed 1.75 inches.
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".
.2528(b) Maintain distance between horizontals at 30" or less pm fence and gate (pre-May 2010). |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed one access hatch standing above grade, corrected during inspection.
Observed left side of pool with several coping stones that need repair prior to next season.