Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSOUTHWOOD CONDOMINIUMS
Address5813 SHARON ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/27/2021
Final Score @ Grade
18
General CommentsNo night swimming permitted. General Comment: Sign posted upon arrival stated pool open until 9:30. Operator stated pool hours were from dawn until dusk. Signage updated. Contact inspector at MCHD if facility wishes for to schedule night swimming permit visit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). -- brick wall barrier near access gates providing foot hold. -- Observed gate between chemical room and restroom is kept locked per operator and not pedestrian access gate. the gate is part of the overall pool barrier and clearance under this gate is > 4" and measures 6 1/2 inches.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed large crack on deck near pool edge measuring 1 inch. CDI, concrete patched / repair made while on-site to prevent potential trip hazard.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter stuck. CDI, repaired while on-site.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. No ventilation in pump and chemical rooms. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Observed no lock and equipment room not kept locked. .2534(6) Provide sufficient lighting in chemical storage room. Observed no light in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No air gap.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Observed no hose bib in bathrooms.